Innovative Flexotech Private Limited
Send Email
0804898314866% Response Rate
Search

Home » Products » Solvent Distillation Unit


Solvent Distillation Unit

Offering you a complete choice of products which include 60 ltr solvent recovery unit, 100 ltr solvent recycling machine, green chemical distillation equipment, solvent recycling cleaning solvent distillation unit, 30 ltr sr solvent recovery unit and paint thinner recycling equipment.

60 Ltr Solvent Recovery Unit

REQUEST CALLBACK

60 Ltr Solvent Recovery Unit
  • 60 Ltr Solvent Recovery Unit
  • 60 Ltr Solvent Recovery Unit
  • 60 Ltr Solvent Recovery Unit
  • +1 60 Ltr Solvent Recovery Unit
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.45 Lakh / UnitGet Latest Price

Product Brochure
Product Details:
Capacity60 ltr
MaterialMild Steel
Automatic GradeAutomatic
Voltage220 V AC
Power5.65 kW
Weight33 kg
Dimensions1300 mm x 880 mm x 1300 mm
Recovery Rate85%
BrandInnovative Flexotech Private Limited

Special Features:

  • Solvent recovery unit for photopolymer flexo plates

 

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating Steps:

  • After opening the crate, plug in power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered
  • Close the lid and tighten it.
  • Check all the pipe hose make sure it is well connected. Especially vacuum pipe and fresh come-out pipe.
  • Set up the thermostat for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa low at 6.01Mpa, and steam cooling fan thermostat at 40 degree C.
  • Turn on the power switch, steam cooling switch, heater switch and vacuum pump switch.
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer then turn on the switch.

 

Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process
Yes! I am interested

100 ltr Solvent Recycling Machine

REQUEST CALLBACK

100 ltr Solvent Recycling Machine
  • 100 ltr Solvent Recycling Machine
  • 100 ltr Solvent Recycling Machine
  • 100 ltr Solvent Recycling Machine
  • +1 100 ltr Solvent Recycling Machine
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 4.5 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Capacity80 ltr
BrandInnovative Flexotech Private Limited
MaterialMild Steel
Voltage220 V AC
Power5.65 kW
Weight33 kg
Dimensions1300 mm x 880 mm x 1300 mm
Recovery Rate85%

We are the prominent enterprise of this domain engaged in offering a wide spectrum of 100 ltr Solvent Recycling Machine. The offered machine is made available with the processing board 1500mm x 980mm x 1500mm. The recovery and recycle rate of the machine is 85 percent with recovery volume of 100L. Provide machine be built applying OEM and ODM standards under the observation of strict professionals. Also, pure stainless steel metal alloy has been used in fabricating the frame.

Features:
  • High quality recycled solvent
  • Clean and pure supply to the production line
  • Durable and stable performance

Other Details:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level.
  • Remove the waste after every recovery process

Operating Steps:

  • After opening the crate, plug in power, and connect the ground earth.
  • Open the lid and fill the tank up to the level with solvent to be recovered
  • Close the lid and tighten it.
  • Check all the pipe hose make sure it is well connected. Especially vacuum pipe  and fresh come-out pipe.
  • Set up the thermostat for example for Perc.is 150 degree C, for green chemical. Vacuum tank pressure high at 0.03 Mpa low at 6.01Mpa, and steam cooling fan thermostat at 40 degree C.
  • Turn on the power switch, steam cooling switch, heater switch and vacuum pump switch.
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer then turn on the switch.
Yes! I am interested

Green Chemical Distillation Equipment

REQUEST CALLBACK

Green Chemical Distillation Equipment
  • Green Chemical Distillation Equipment
  • Green Chemical Distillation Equipment
  • Green Chemical Distillation Equipment
  • Green Chemical Distillation Equipment
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.5 Lakh / UnitGet Latest Price

Product Brochure
Product Details:
Usage/ApplicationConstruction
Recovery Volume80 Liter
Voltage220 V AC
Power5.65 kW
Weight33 kg
Dimensions1300 mm x 880 mm x 1300 mm
Recovery Rate85%
Frequency50 Hz

We feel proud to introduce ourselves as the leading organization in this domain, engaged in producing an excellent grade Green Chemical Distillation Equipment. This equipment is manufactured using quality grade stainless steel frame and other metal alloys. The offered equipment is made of adhering to industry standards that include OEM and ODM guidelines. Also, under the strict observation and guidelines, the offered equipment is fabricated. In addition, the equipment is tested for quality before dispatching to the clients.

Features:

  • Robust construction
  • Anti rust properties
  • Less noise and low power consumption

Other Details:
  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process

Operating Steps:

  • After opening the crate, plug in power, and connect the ground earth.
  • Open the lid and fill the tank up to the level with solvent to be recovered.
  • Close the lid and tighten it.
  • Check all the pipe hose make sure it is well connected. Especially vacuum pipe and fresh come-out pipe.
  • Set up the thermostat for example for Perc.is 150 degree C, for green chemical. Vacuum tank pressure high at 0.03 Mpa low at 6.01Mpa, and steam cooling fan thermostat at 40 degree C.
  • Turn on the power switch, steam cooling switch, heater switch and vacuum pump switch.
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer then turn on the switch.
Yes! I am interested

Solvent Recycling Cleaning Solvent Distillation Unit

REQUEST CALLBACK

Solvent Recycling Cleaning Solvent Distillation Unit
  • Solvent Recycling Cleaning Solvent Distillation Unit
  • Solvent Recycling Cleaning Solvent Distillation Unit
  • Solvent Recycling Cleaning Solvent Distillation Unit
  • Solvent Recycling Cleaning Solvent Distillation Unit
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3.3 Lakh / UnitGet Latest Price

Product Brochure
Product Details:
Capacity60 Liters
MaterialMild Steel
Voltage220 V
Power4.65 KW
Diathermic Oil23 kg
Dimensions1100 X 780 X 1200 mm
Recovery Rate85%
Recovery Time4 hours
BrandInnovative Flexotech Private Limited

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Technical information:

  • Recovery Volume: 80 Liters


Operating Steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process
Yes! I am interested

30 Ltr SR Solvent Recovery Unit

REQUEST CALLBACK

30 Ltr SR Solvent Recovery Unit
  • 30 Ltr SR Solvent Recovery Unit
  • 30 Ltr SR Solvent Recovery Unit
  • 30 Ltr SR Solvent Recovery Unit
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.95 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Usage/ApplicationConstruction
Automation GradeSemi-Automatic
Capacity30 ltr
FinishingPolished
Frequency50 Hz
Power SourceElectric
Voltage220 V
Power5.65 kW
Weight33 kg
Dimensions1300 mm x 880 mm x 1300 mm
Recovery Rate85%

Special Features:

  • Solvent recovery unit for photopolymer flexo plates

 

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating Steps:

  • After opening the crate, plug in power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered
  • Close the lid and tighten it.
  • Check all the pipe hose make sure it is well connected. Especially vacuum pipe and fresh come-out pipe.
  • Set up the thermostat for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa low at 6.01Mpa, and steam cooling fan thermostat at 40 degree C.
  • Turn on the power switch, steam cooling switch, heater switch and vacuum pump switch.
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer then turn on the switch.

 

Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process
Yes! I am interested

Paint Thinner Recycling Equipment

REQUEST CALLBACK

Paint Thinner Recycling Equipment
  • Paint Thinner Recycling Equipment
  • Paint Thinner Recycling Equipment
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 4.5 Lakh / UnitGet Latest Price

Product Brochure
Product Details:
Usage/ApplicationConstruction
Automation GradeSemi-Automatic
Voltage220 V
Power4.65 kW
Diathermic Oil23 kg
Dimensions1100 X 780 X 1200 mm
Recovery Rate85%
Recovery Volume80 Liters

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Technical Information:

  • Recovery volume: 60 liters
  • Recovery time:  4 hours

 

Operating Steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process
Yes! I am interested

Toluene Distillation System

REQUEST CALLBACK

Toluene Distillation System
  • Toluene Distillation System
  • Toluene Distillation System
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 5.5 Lakh / UnitGet Latest Price

Product Brochure
Product Details:
MaterialMild Steel
Usage/ApplicationConstruction
Power5.65 kW
Weight33 kg
Voltage220 V AC
Dimensions1300 mm X 880 mm X 1300 mm
Recovery Rate85%

Special Features:

  • Solvent recovery unit for photopolymer flexo plates

 

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating Steps:

  • After opening the crate, plug in power, and connect the ground earth.
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe hose make sure it is well connected. Especially vacuum pipe and fresh come-out pipe.
  • Set up the thermostat for example for Perc.is 150 degree C, for green chemical. Vacuum tank pressure high at 0.03 Mpa low at 6.01Mpa, and steam cooling fan thermostat at 40 degree C.
  • 6. Turn on the power switch, steam cooling switch, heater switch and vacuum pump switch.
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer then turn on the switch.


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level
  • Remove the waste after every recovery process
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Alpesh Thakar (CEO)
Innovative Flexotech Private Limited
No. 435, Patel Avenue, Near Gurudwara Thaltej
Ahmedabad - 380059, Gujarat, India
Call Us: 
Call Response Rate: 66%
Share Us :



Home  |   About Us   |  Products  |  Site Map  |   Contact Us

© Innovative Flexotech Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Innovative Flexotech Private Limited