Innovative Flexotech Private Limited
Send Email
Call 0804876244177% Response Rate
Search

Home » Products » Solvent Recycling System


Solvent Recycling System

Manufacturer of a wide range of products which include solvent recovery distillation plant, solvent recovery system, 200 liter solvent distillation unit, toluene distillation system, xylene solvent distillation unit and 60 liter solvent distillation unit.

Solvent Recovery Distillation Plant

REQUEST CALLBACK

Solvent Recovery Distillation Plant
  • Solvent Recovery Distillation Plant
  • Solvent Recovery Distillation Plant
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.95 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
BrandInnovative Flexotech
Power Consumption4.65 kW
Frequency60 Hz
Power SourceElectric
Voltage220 V
Country of OriginMade in India
Recovery Volume80 Liter
Diathermic Oil23 kg
Dimensions1100 x 780 x 1200 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

Solvent Recovery System

REQUEST CALLBACK

Solvent Recovery System
  • Solvent Recovery System
  • Solvent Recovery System
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.95 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Country of OriginMade in India
Power SourceElectric
Voltage220 V
Frequency60 Hz
PhaseThree Phase
Recovery Volume60 Liter
Power Consumption4.65 kW
Diathermic Oil23 kg
Dimension1100 x 780 x 1200 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

200 Liter Solvent Distillation Unit

REQUEST CALLBACK

200 Liter Solvent Distillation Unit
  • 200 Liter Solvent Distillation Unit
  • 200 Liter Solvent Distillation Unit
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 6.45 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Country of OriginMade in India
Power SourceElectric
Voltage380 V
Frequency60 Hz
PhaseSingle Phase
Body MaterialStainless Steel
Recovery Volume200 Liter
Power Consumption10 kW
Diathermic Oil23 kg
Dimension2500 x 1700 x 2300 mm
Recovery Rate85%
Recovery Time6 ~ 7 hours

Since our inception, we are engaged in offering a wide range of excellent quality 200 Liter Solvent Distillation Unit. This machine helps in cleaning and distillation the chemical components and substances from the plate, rod and other equipment. It can clean entire types of solvent from the chemically dip solvents. Additionally, the control panel and one production line helps in increasing the product supply in a unit. Along with it, clients can get the unit from us at industry leading rates also within the stipulated period.

Features:

  • High power consumption
  • Easy stages for quick production
  • Less noise


Other Details:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process

Operating Steps:
  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).
Yes! I am interested

Toluene Distillation System

REQUEST CALLBACK

Toluene Distillation System
  • Toluene Distillation System
  • Toluene Distillation System
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 6.45 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
BrandInnovative Flexotech
Dimension1100 x 780 x1200 mm
Country of OriginMade in India
Power SourceElectric
Voltage210 V
Frequency60 Hz
PhaseThree Phase
Recovery Volume80 Liter
Power Consumption4.65 kW
Diathermic Oil23 kg
Recovery Rate85%
Recovery Time3 ~ 4 hours

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.

Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

Xylene Solvent Distillation Unit

REQUEST CALLBACK

Xylene Solvent Distillation Unit
  • Xylene Solvent Distillation Unit
  • Xylene Solvent Distillation Unit
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.75 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Country of OriginMade in India
Recovery Volume80 Liter
Power Consumption4.65 kW
Diathermic Oil23 kg
Dimension1100 x 780 x1200 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours
Power SourceElectric
Frequency60 Hz
PhaseThree Phase

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel.
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters).
  • Remove the waste after every recovery process.
Yes! I am interested

60 Liter Solvent Distillation Unit

REQUEST CALLBACK

60 Liter Solvent Distillation Unit
  • 60 Liter Solvent Distillation Unit
  • 60 Liter Solvent Distillation Unit
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.95 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Design TypeStandard
Country of OriginMade in India
Power SourceElectric
Voltage220 V
Frequency60 Hz
PhaseThree Phase
Recovery Volume60 Liter
Power Consumption4.65 kW
Diathermic Oil23 kg
Dimension1100 x 780 x 1200 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

Solvent Washout Chemical Recycling Machine

REQUEST CALLBACK

Solvent Washout Chemical Recycling Machine
  • Solvent Washout Chemical Recycling Machine
  • Solvent Washout Chemical Recycling Machine
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.95 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
BrandInnovative Flexotech
Dimension1100 x 780 x 1200 mm
Country of OriginMade in India
Recovery Volume60 Liter
Voltage220 V
Power Consumption4.65 kW
Recovery Rate85%
Recovery Time3 ~ 4 hours
Frequency60 Hz

General description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

30 Liter Solvent Recovery System

REQUEST CALLBACK

30 Liter Solvent Recovery System
  • 30 Liter Solvent Recovery System
  • 30 Liter Solvent Recovery System
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.75 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
BrandInnovative Flexotech
Power Consumption3.65 kW
Automatic GradeAutomatic
Country of OriginMade in India
Power SourceElectric
Voltage220 V
Frequency60 Hz
Recovery Volume30 Liter
Diathermic Oil20 kg
Dimensions960 x 610 x 940 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours

With the assistance of our deft team of professionals, we are able to introduce a broad array of 30 Liter Solvent Recovery System. It is one of the environment friendly systems available in the industry. The system finds wide application use in recycling dirty solvent whether used or waste solvent. In various industrial processes where organic or non-organic substances are used, such recovery system helps in cleaning and recycling solvent from the machines. In addition, the system provides perfect distribution to production line.

Features:

  • 32 stages of control function
  • Less in material consumption
  • Low maintenance cost

Other Details:
  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process

Operating Steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).
Yes! I am interested

Acetone Solvent Recovery Equipment

REQUEST CALLBACK

Acetone Solvent Recovery Equipment
  • Acetone Solvent Recovery Equipment
  • Acetone Solvent Recovery Equipment
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.3 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Country of OriginMade in India
Power SourceElectric
Voltage220 V
Frequency60 Hz
PhaseThree Phase
Recovery Volume80 Liter
Power Consumption5.65 kW
Diathermic Oil33 kg
Dimensions1300 x 880 x 1300 mm
Recovery Rate85%

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch (15), steam cooling switch (16), heater switch (17) and vacuum pump switch (12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

Solvent Recovery Equipment

REQUEST CALLBACK

Solvent Recovery Equipment
  • Solvent Recovery Equipment
  • Solvent Recovery Equipment
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.3 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Country of OriginMade in India
Power SourceElectric
Voltage220 V
Frequency60 Hz
PhaseThree Phase
Recovery Volume80 Liter
Power Consumption5.65 kW
Diathermic Oil33 kg
Recovery Rate85%
Dimension1300 x 880 x 1300 mm

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch (15), steam cooling switch (16), heater switch (17) and vacuum pump switch (12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

Waste Solvent Recycler

REQUEST CALLBACK

Waste Solvent Recycler
  • Waste Solvent Recycler
  • Waste Solvent Recycler
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1.95 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
Brand/MakeInnovative Flexotech
Country of OriginMade in India
Power SourceElectric
Voltage220 V
Frequency60 Hz
PhaseThree Phase
Recovery Volume60 Liter
Power Consumption4.65 kW
Diathermic Oil23 kg
Dimension1100 x 780 x 1200 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours

General Description:

  • This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.


Operating steps:

  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).
  • If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).


Important:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process.
Yes! I am interested

60 Liter Thinner Recovery Equipment

REQUEST CALLBACK

60 Liter Thinner Recovery Equipment
  • 60 Liter Thinner Recovery Equipment
  • 60 Liter Thinner Recovery Equipment
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2.5 Lakh / UnitGet Latest Price

Product Details:
Minimum Order Quantity1 Unit
BrandInnovative Flexotech
Automatic GradeAutomatic
Voltage220 V
Frequency60 Hz
PhaseThree Phase
Power SourceElectric
Recovery Volume80 Liter
Power Consumption4.65 kW
Diathermic Oil23 kg
Dimensions1100 x 780 x 1200 mm
Recovery Rate85%
Recovery Time3 ~ 4 hours

Leveraging on our in-house production unit, we are offering a wide assortment of 60 Liter Thinner Recovery Equipment. This equipment can easily be used for recycling solvent according to the distillation principle. Furthermore, the equipment find wide application use in a variety of industries that use organic solvent as cleaning agent such as dirty solvent from cleaning the spray gun, trichloroethylene from cleaning electronic products, toluene, anhydrous alcohol, and IPA used as cleaning the optical lens. This machine is eco-friendly and do not contaminate the elements present in environment.

Features:

  • High quality recycled solvent
  • Clean and pure supply to the production line
  • Durable and stable performance


Other Details:

  • Install the unit in a wide and ventilated place.
  • Disconnect electric power before doing any action.
  • No taking off the control panel
  • Change the diathermic oil every 1000 working hours.
  • No filling the solvent container up over the level (80 liters)
  • Remove the waste after every recovery process

Operating Steps:
  • After opening the crate, plug in 220 V power, and connect the ground (earth).
  • Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
  • Close the lid and tighten it.
  • Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1).
  • Set up the thermostat(18) for example for Perc.is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure(3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat(11) at 40 degree C.
  • Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12).If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13).
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Alpesh Thakar (CEO)
Innovative Flexotech Private Limited
No. 435, Patel Avenue, Near Gurudwara Thaltej, GIDC Vatwa
Ahmedabad - 380059, Gujarat, India
Call Us: 
Call Response Rate: 77%
Share Us :



Home  |   About Us   |  Products  |  Site Map  |   Contact Us

© Innovative Flexotech Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Innovative Flexotech Private Limited